Garrett J. Young's Research (E-mail)
| Home - Quasi-Elliptical Torsatron
(2000-2001) |
Isolating Plasma Species (1999-2000) |
Inertial Electrostatic
Confinement |
Technical & General Publications (1999-2002) |
Google™ Powered Site
Search
Tips for Inertial Electrostatic Confinement Fusion
Investigators
(A Supplement to article "The World's Simplest Fusion Reactor, and How to
Make It Work", published in the December 1998 Analog magazine, a Dell
publication.)
by Tom Ligon (tomligon@compuserve.com)
This document may be copied and distributed, with proper attribution, in
any manner intended to constructively support the field of electrostatic
fusion research. Please refrain from posting it with any safety information
deleted. Also, you must accept full responsibility for your use of this
information, which cannot possibly be all-inclusive, or cover all possible
safety concerns.
Acknowledgment: The unaccredited photograph on the title page of
the article referenced above was produced by Richard Hull, the Tesla coil
guru of TCBOR. The photo shows a machine he built after reading a draft of
the article and witnessing a demonstration of an early machine of mine.
INTRODUCTION
This is intended primarily for those who have read my article "The
World's Simplest Fusion Reactor, and How to Make It Work" in the December
1998 Analog magazine. In that article, I describe a simple machine,
variously called a Farnsworth Fusor or Hirsch/Farnsworth machine, composed
of concentric electric grids in a vacuum chamber, which is capable of doing
controlled hot nuclear fusion (well below breakeven). The device is
characterized in the article as being so simple it could be done as a high
school science project.
This is not some hocus-pocus pseudoscience, nor even a controversial new
discovery of some mysterious phenomenon. This is a working hot-fusion
technology, which has been proven to work in one lab after another, for
decades. It is based on straightforward classical physics. The key concept
is Inertial Electrostatic Confinement (IEC) using either direct Ion
Acceleration (IXL) or indirect ion acceleration using an Electron
Acceleration (EXL) potential well. Ions are electrostatically accelerated in
the same manner as in primitive linear particle accelerators, but
spherically so that they converge to a high-density region.
Just because the machine is simple, and could potentially be built by a
high-school student, this does not mean it is perfectly safe, or should be
attempted without a knowledgeable advisor. On the contrary, aspects of it
are lethally dangerous, and it is quite capable of doing nuclear reactions
which should be done only with the advice and supervision of someone
competent in "Health Physics" (nuclear safety), high voltage, and laboratory
practices.
The machine described in the article operates at around 10,000-15,000
volts, at currents sufficient to be lethal! Voltages this high can arc,
corona, leak, and otherwise find their way into your body under
circumstances where more common voltages may be perfectly safely contained.
It cannot be stressed enough that strict high voltage safety practices must
be followed at all times.
Other hazards exist in this project as well. It involves the use of
vacuum equipment and pressurized, flammable gases, either of which can be
dangerous. The construction is left largely to the individual researcher,
but certainly one must use good safety practice in whatever shop skills are
employed, and choose parts and materials safe and suitable for the job. The
device described is barely capable of producing a detectable nuclear
reaction, so this is actually one of the least of the hazards, but raising
the voltage and power of the device, operating it for an extended time, or
making other performance enhancements could potentially constitute a nuclear
hazard.
READ AND UNDERSTAND ALL OF THE SAFETY TIPS BELOW, AND BECOME
FAMILIAR WITH GENERAL LABORATORY SAFETY AND FIRST AID, AND BE SURE SOMEONE
IS ON HAND WHO CAN RENDER AID IN CASE OF AN ACCIDENT.
Neither Tom Ligon nor Analog accepts any responsibility for any
death, accident, injury, screw up, financial loss, boo-boo, glowing in the
dark, curled hair, browned shorts, or failure of the experimenter to hold
proper health, property, and liability insurance. Stupidity, as Heinlein
noted, is a CAPITAL OFFENSE!
GET AN ADVISOR, MAYBE MORE THAN ONE
Unless you are already skilled in all of the many fields required to
build a working device, you are strongly warned to obtain assistance from
someone who is. For a high-school student, or any relatively inexperienced
worker, this probably means getting advice and supervision in virtually
every hands-on aspect. I am particularly concerned about the immediate and
deadly danger posed by the high voltage at which these devices operate, but
there are also other hazards, some of which are potentially insidious, with
their effects not becoming apparent for years.
While the nuclear danger of the device described in the article is
expected to be minimal if built and operated as described, it is intended to
produce "fast neutrons", a form of radiation with a very high "relative
biological effectiveness", in other words -- especially deadly in high
enough doses. Even if only a low and tolerable dose is expected, the dose
should be verified. Also, since the proof of doing deuterium fusion is
production of the characteristic fast neutrons that reaction produces, you
will most certainly want to detect and quantify them. The methods and
equipment for doing this are no trivial problems for the typical high-school
student to solve.
Thus, one very important advantage of finding someone skilled in Health
Physics (radiation safety) is that they may be able to loan you equipment
and/or help you find scarce materials and equipment, possibly saving you a
small fortune. They can also help verify your claims of detecting neutrons.
If you are unable to find an advisor in a critical hardware phase, I
recommend that you adjust the scope of your endeavor. While you may get more
radiation exposure from days in front of a computer CRT than you would from
a few minutes of operation of a machine intended to barely make detectable
fusion, I think few people would consider computer simulations of IEC fusion
devices to be too hazardous for a high school student. This is a field which
has not been exhausted. Although typically tackled at the graduate level by
Masters and Ph.D. candidates, a sharp calculus whiz, particularly one with
the talent to compete nationally at the high-school level, might reasonably
make a meaningful contribution to the field. If you can get good advisors
for fabrication, high voltage methods, vacuum, gas handling, etc., but not
nuclear safety, you could build the machine but run it on ordinary hydrogen,
still an interesting demonstration but without the nuclear aspect.
HIGH VOLTAGE POWER SUPPLY SAFETY
The equipment described can cause INSTANT DEATH, painful shock or
burns, and severe secondary injuries due to sudden involuntary muscle
movement.
The machine described in the article can produce voltages approaching
15,000 volts. The power source described is a 15 kV (15,000 V RMS), 60 mA 60
Hz alternating-current neon sign transformer. Transformers of this type are
centertapped, that is the two high voltage terminals are each 7500 V RMS off
of case ground, and the center tap is attached to the transformer's metal
case. They are not constructed to be used in any other manner.
I once new a perfectly intelligent engineer who tried to ground one
terminal of a neon sign transformer, use the other as the hot terminal at
15000 volts, and allow the transformer case to "float". So it floated to
7500V, and arced to the 120 V power leads coming in. BAD IDEA!
The 7500V value is RMS (root-mean-square) which means something similar
to "average" (RMS voltage times RMS current gives actual average power in
resistive loads). The voltage actually varies as a sine wave at 60 Hz AC,
and the peak value is 1.414 x the RMS value. Thus, the peak value would be
expected to be 10,600 V. Actually it is a little higher, and may exceed
13,000V. The reason for this is that the transformer voltage is rated for
use under load, and with no load the voltage will be somewhat higher.
The most natural way to convert the output of a transformer of this type
to DC is to use a pair of high voltage diodes (rated at above the full
current capacity of the transformer and over twice the peak voltage) to
produce a Full Wave Center-Tapped Rectifier circuit. This type of circuit is
described in most basic electronic texts. The diodes should each "point
toward" the transformer high voltage terminals so that the supply produces
negative output. HOWEVER, IT IS IMPORTANT TO REALIZE THAT, WHILE THE
CIRCUIT SCHEMATIC IS VERY "ORDINARY", THE CONSTRUCTION METHODS ARE QUITE
SPECIAL IN ORDER TO SAFELY HANDLE THE VOLTAGE!
High voltage diodes may be tricky to find. Some possible sources of
supply are given at the end of this article, although a few may not care to
deal with amateurs or in small quantities. There are specialty outfits that
produce diodes directly capable of handling the required conditions, about
30 kilovolts (twice the peak supply voltage plus a margin) at 100 milliamps
being the minimum rating recommended for the transformer specified. If you
are unable to get such high-performance parts, you might consider using
diodes for microwave oven power supplies, typically capable of 12kV at 300
mA. Three such diodes connected in series would suffice to replace one 30kV
diode. You could even work with 1kV diodes, with 30 in series, encased in
epoxy. This may or may not work due to any number of possible problems, but
since such diodes in quantity are pennies apiece, if care is taken so a
failure produces nothing worse than the stink of burned parts it is a
possible alternative.
It is recommend that the neon sign transformer be powered by an
adjustable autotransformer, sometimes called by a trade name such as Variac.
The neon sign transformer will draw around 7 amps, and so an autotransformer
capable of delivering 10 amps is the best size to use. If one cannot be
found used or borrowed, a source of supply for an economy model is listed at
the end of this article. Use of an autotransformer allows you to bring the
voltage up slowly, avoiding damage if the system is run at too high a
pressure, or while conditioning the grids.
It is customary in such circuits to employ a "filter capacitor". This can
be done at high voltage as well, but you must be aware that it greatly
increases the hazards associated with the circuit. First, a capacitor can
store a lethal charge for hours or days after the apparatus is turned off.
Second, a capacitor makes it possible for the apparatus to produce brief
pulses of current vastly above the capacity of the transformer. Finally,
while not a safety issue, a large capacitor will usually make grid damage
more of a problem for gridded IEC machines. It is possible to make a
demonstration machine without a filter capacitor, and unless you are willing
to accept the extra danger I recommend you work without a filter capacitor.
A strong, securely connected, and easily seen grounded safety lead should
be installed on the equipment. This should have an insulated probe, plug, or
clip which can be attached to the high voltage circuit to drain off any
charge and assure the system is not dangerous. You should not work near or
touch any high voltage circuit unless you can SEE this ground connection is
good and can SEE the power is off and the supply unplugged.
Warning lamps to show power is on are an excellent idea, however remember
that lamps can burn out, so don't trust a lamp to tell you a circuit is
dead, just use it to warn you a circuit is live.
Do not try to build a high voltage circuit on an ordinary circuit board,
particularly the cheap phenolic type with cellulose fibers. Don't use wood.
Don't use cardboard. Don't use anything that you are not absolutely
confident can handle the voltage! Among the better materials, you could
consider Lexan (polycarbonate) sheet, garolite high-performance phenolic
intended for high voltage use), and porcelain. Plexiglas (or other acrylic)
also works well but is a problem to cut and drill. My own preference is to
use cylindrical porcelain standoffs on a polycarbonate board, with the
components connected between the porcelain standoffs. The insulators must be
kept clean -- any moisture, sweat, or other contamination can cause leakage
of current. Porcelain insulators (frequently used in high-power
transmitters, particularly those built to military specifications) can
sometimes be found surplus and can be bought new from better electronic
supply houses. Good plastic insulators can also be used and can be bought or
fabricated.
Adequate component spacing must be allowed. The voltage employed can
easily jump 1-2 centimeters, producing a vicious arc. It can also produce
coronas (sizzling halos of ionized air) particularly if the air is humid.
Either arcs or coronas will produce ozone, a highly reactive form of
oxygen that can rot rubber and peel the paint off of walls, so just imagine
what it does to your lungs and eyes! Ozone has a sharp, "fresh" smell. If it
starts to build up you should ventilate the work area. It can also be
destroyed by circulating it over an activated charcoal filter. It is also
often produced by laser printers and photocopiers, and the same measures
should be used to control ozone from them.
The power supply should be enclosed to prevent accidental contact. It is
very easy, when handling a piece of wire or a long metal object, to
accidentally come in contact with a high voltage circuit. The enclosure can
be wood (if spaced well away from the electrical components and wiring),
plastic, or metal (if electrically grounded and spaced well away from the
components and wiring).
Inside the power supply enclosure, ordinary wiring may be used, even
uninsulated wiring, if the spacing is adequate. Some insulation will, in
fact, catch fire if exposed to a high voltage arc, and thin electrical
insulation will do little to protect against such arcs anyway. BUT ...
OUTSIDE THE ENCLOSURE OF THE POWER SUPPLY you must use specially
insulated high voltage wire. Such wire is sold for making neon signs, or you
could consider using non-resistance spark plug wire. Some electronic supply
houses may also have wire with very high voltage insulation. It is best to
supplement the insulation with an extra layer, with "Teflon" or similar
fluorocarbon tubing being a good choice. The outer tubing helps protect the
inner insulation from cuts, scrapes, etc, and may prevent arcing from unseen
pinholes or cuts in the primary wire insulation. It is also a good idea to
support and route the wire through good PVC electrical conduit to as great a
degree as practical. Avoid polyethylene tubing or other materials which
could catch fire in an arc.
The electrical feedthrough carrying high voltage into the test chamber
typically has an exposed terminal. This terminal should be covered to
prevent accidental contact. A plastic cup can be slotted and fixed over the
insulator to do this (allow at least 2 cm of space between the terminal and
cup), or the terminal can be insulated with a heavy application of
electricians splicing tape (a gummy, stretchy, rubbery tape that seals to
itself and forms an excellent high voltage insulation, which MUST NOT BE
CONFUSED WITH ORDINARY VINYL ELECTRICAL TAPE.
Measuring current to the test is tricky. You could attach a milliamp
meter in the high voltage output lead, but it would have to be enclosed in
an insulated box, and covered with a thick, clear plastic cover. More
commonly, the meter is attached in the ground lead connecting the test
chamber to the high voltage supply. IT IS ABSOLUTELY IMPERATIVE THAT ANY
METERING CIRCUIT IN THE GROUND LINE BE SECURELY WIRED IN SO THAT IT CANNOT
BE DISCONNECTED! FAILURE TO DO SO CAN MAKE THE DISCONNECTED PART OF THE
SYSTEM GO TO HIGH VOLTAGE! In otherwords, don't hook up an ordinary
multimeter, quipped with banana plug or pin leads, in this role, nor use
clip leads, unless you have a DEATH WISH!
Some part of the system MUST be electrically grounded (hooked to
the building electrical ground). For example, if using conventional US NEMA
5-15 120V household power outlets you could ground the system by the U-prong
of the power cord, and you might also connect to a secondary ground such as
a metal electrical conduit. The only way to avoid this would be to put the
whole apparatus in a big insulated box and never touch it. I would recommend
grounding the test chamber case (assuming it is metal or has a metal base),
and electrically isolating the transformer case, which should be enclosed
with the high voltage components. The transformer case is then grounded
through the current metering circuit. You cannot directly ground both
transformer and test chamber if you use a meter between them.
It is also a really good idea to have a second ground path between the
test chamber and the high voltage supply in which a pair of low-voltage
zener diodes in series but opposite polarity are used. If the meter should
become disconnected or faulty, this path would limit the voltage to about
the zener breakdown voltage. This can also be done with several regular
silicon diodes in series, with two such sets in parallel (these will start
to conduct at about 0.6V per diode). Choose the components so that the meter
you are using operates at a much lower voltage drop, otherwise the meter
will read too low.
Measuring high voltage is also tricky. You can buy a special probe which
attaches to a digital multimeter, which divides the voltage by a factor of
1000. This allows you to read the meter so that volts become kilovolts.
However, you can also build-in a voltage divider to the circuit. Don't
expect to find the resistors to do this at Radio Shack -- in fact they can
be quite hard to find at all. A source of surplus parts is listed at the end
of the article which usually stocks them. The resistor to measure this
circuit will typically be about a gigaohm (that's a billion ohms) and should
be several inches long to handle the voltage safely (resistors of that
physical size and resistance will handle the power, too). Be aware that if
you hook such a resistor up to an ordinary ohm-meter the meter will think
the resistor is an open circuit. Also be aware that a greasy handprint or
any moisture down the side of the resistor will throw its resistance way
off. Also be aware that the amount of current flowing through such a
resistor is insufficient to move even the most sensitive mechanical meter
movement -- you need to use a high-impedance electronic meter, which
typically means a digital meter. The meter must be shunted with a second
resistor, which can be a plain-old low-voltage type, with the value selected
to give the desired reading on the meter. Any basic electronics book will
describe how to build a voltage divider. You will need to borrow a
calibrated high voltage meter to tweak the circuit for full accuracy (gigaohm
resistors are not generally very precise, especially the surplus variety).
An additional benefit to using a built-in voltage divider is that it will
help bleed off the charge when you turn the system off. This is especially
vital if you decide to use a filter capacitor. Be aware that the rate of
discharge will probably be very slow, and the bleed should not be used in
place of a grounded safety strap.
Note: Be sure the components used can easily handle the full power
of the power supply shorted through them.
The transformer specified is designed to be internally current-limited,
but the current limit is not a hard-and-fast number, nor is it based on a
simple resistance. It can put out somewhat above 60 mA, and if filter
capacitors are used it can momentarily put out amps, tens of amps ...
kiloamps, hey, how big a capacitor did you put on that sucker, anyway? As a
general rule, anything over 50mA is considered capable of killing a healthy
adult.
CAPACITOR AND INDUCTOR FILTERS
Go back and read the hazards described in the section above about using
capacitors.
If you do choose to use a filter capacitor on your power supply, you will
greatly magnify a pesky effect that Hirsch-type IEC machines experience:
bright flashes from the central grid. These probably should be classified as
"pulsed anomalous glow discharge" (you Infinite Energy subscribers
will suddenly perk your ears up). These occur most frequently with newly
installed grids, and must be gradually "burned out" by slowly raising the
voltage. They probably result from contamination on the grid by "low
work-function" materials (things which give up electrons easily). The alkali
elements do this, as do diamond films and certain other forms of carbon.
Fingerprints should be suspected.
If the filter capacitor is large enough to significantly reduce ripple at
currents in the 20 mA and above range where detectable fusion is likely, you
can expect the flashes to be highly destructive. You may find sections of
grid missing from time to time. Your options are to under-filter the power
supply, or add inductive filtering, which suppresses sudden current pulses.
Both capacitive and inductive filtering techniques are covered in the
Amateur Radio Handbook published by the American Radio Relay League, and in
other electronics texts.
The problem is, the required inductor size will be quite large, and it
may be impractical to buy one which is capable of standing the high voltage
of these supplies. There is a poor-boy alternative. You can buy a toroidal
inductor or inductor core (the powerded iron type is best, and replace the
windings with teflon-insulated wire to improve the high voltage performance.
This will probably result in an inductor too small to reach the "critical
value" calculated for good filtering. However, one additional trick will
make it pretty effective at killing the destructive flashes -- add a single
turn of heavy wire shorted to itself. This turns the inductor into a
transformer, one with a short-circuited secondary. Any sudden pulse through
the coil will induce a large current in the shorted loop, and really take
the wind out of the pulse. This wastes some energy, but the energy it wastes
is energy that would go into vaporizing the grid.
RADIATION HAZARDS
The apparatus described can produce three types of harmful radiation:
x-rays, ultraviolet, and neutrons.
X-rays are produced when high energy electrons strike high-atomic-number
targets. Electrons coming from the inner grid and hitting stainless steel
walls or outer grid wires would be possible sources. Colliding high-energy
ions can also release essentially identical radiation (physicists may
nit-pick over the name, but the hazard and precautions are essentially
unchanged). If you stay below 15 kV the x-ray problem should not be serious,
and a thin metal barrier (like metal chamber walls) should all but stop
them. Your computer monitor cranks out worse x-rays, and is also shielded
with thin metal. If, on the other hand, you decide to join the ranks of the
serious researchers and crank up the voltage, you must absolutely take
appropriate precautions, which are beyond the scope of this article.
Electrical discharges in hydrogen gas are commonly used to produce
ultraviolet radiation at short wavelengths. This is pretty hot radiation,
the sort that can cause a rapid "sunburn", eye damage, and skin cancer.
Fortunately, it doesn't penetrate glass very well. I've been told it also
does not penetrate clear plastics, but an itchy sensation on my cheeks tells
me otherwise.
While it is possible to make a low-grade Fusor in a plastic vacuum
dessicator chamber, I do not recommend it and three of the reasons are that
it will not stop x-rays, may not stop UV, and also can't take heat, which
the Fusor will produce. Plastic chambers are also prone to outgassing and
are difficult to get down to the required pressure. Trust me, I tried a
plastic vacuum chamber, and it is a waste of money as well as a possible
danger.
Neutrons are neutral subatomic particles, which will go right through the
walls of the test chamber, hardly affected. In most cases, fears that
"radiation" (x-rays, gamma rays, alpha particles, and beta particles) will
make things radioactive are just plain ignorance. But neutrons CAN
make things radioactive. When they hit another nucleus and are absorbed into
it, they cause elemental transmutations, frequently into unstable isotopes.
Beyond that, neutrons coming off of deuterium fusion reactions have
hellacious energy, several million electron volts worth. They hit HARD,
knocking atoms clean out of molecules and causing other unhealthy effects on
living things. One would be well advised to avoid being hit by too many of
these nasty little buggers, which are just about the worst type of radiation
you can encounter.
Fortunately, the machine described, operating at under 15kV, does not
make many neutrons. Operating at the most optimistic output, based on one
really good 15-second burst I saw using a larger power supply, the machine
should not be able to produce more than about 300,000 neutrons a second,
which would require 12 days at 1 meter away before you picked up a dose high
enough to even START to worry. This on a machine on which the grid
life is probably under 20 minutes if the grid is made of stainless steel.
More likely neutron production will be down in the hard-to-detect range of
under 10,000 per second. These will radiate off spherically, so only a
fraction will hit someone standing to one side.
The best shielding for most radiations, neutrons and x-rays included, is
the inverse square law. Put some distance between you and the source. An
excellent neutron shield is water "poisoned" with boron. Fill a large trash
can with water and dissolve a box of borax (yup, the 20 mule-team laundry
product will do just fine) in it, then put the trash can between you and the
Fusor. Boron is a really aggressive neutron absorber frequently used to kill
fission reactions. You can also add a little boric acid to it and use it to
make your Halloween or Christmas pageant costume fire retardant, and I'll
wager if you have a cockroach problem it will soon go away. It is a little
toxic (read the box), so keep pets and small children away.
Watching the glow of the reaction through a mirror would allow you to
stay behind such a neutron shield. X-rays will not reflect from a glass
mirror. With such precautions the radiation hazard from the machine
described would be virtually zero.
Deuterium gas is not radioactive. It is a stable isotope of hydrogen
found in nature in trace quantities, and can generally be purchased without
special license from compressed gas suppliers, including some welding supply
houses. Tritium gas, on the other hand, is quite radioactive, and can only
be purchased and used with a special license and safety precautions. The use
of tritium gas for these experiments is definitely NOT recommended
except when conducted by properly licensed facilities run by knowledgeable
experimenters and overseen by professional Health Physicists.
FABRICATION SAFETY
As stated earlier, the great variety of fabrication techniques that could
potentially be employed go far beyond any ability to address in this
article. Please do not attempt to do any potentially hazardous operations
without adequate instruction, supervision, and safety equipment.
In most, if not all, cases, this means wearing APPROPRIATE EYE
PROTECTION.
In some cases, this may also require wearing HEARING PROTECTION.
Operations producing dust or noxious gases may require BREATHING
PROTECTION.
Operations involving toxic compounds require APPROPRIATE EXPOSURE
PROTECTION and SAFE DISPOSAL.
One operation does warrant special mention, as it is somewhat unusual and
is likely to be needed in virtually all implementations of this apparatus.
The absolute best way to physically support and get high voltage to the
central grid of a Hirsch-type fusor is by running a wire through a
CERAMIC TUBE, and the best choice for the tube is ALUMINA, an
oxide of aluminum. Alumina tubing is readily available and not too expensive
in the sizes and amounts needed for this work. However, it is the darndest
stuff to work with you ever saw -- its strength and hardness are simply
amazing. It defies ordinary tools, and usually cannot be cut by simple
scoring as glass tubing can. The best way I have found to cut alumina tubing
is using a high-speed mini-grinder (Moto-Tool or similar) and a diamond
abrasive cutoff wheel. Don't even bother with the usual abrasive wheels for
this type of tool as they simply disintegrate when they hit alumina. Small
diamond wheels for these tools are not too expensive, typically under $20
for a set of 5 blades. Special safety precautions apply to cutting alumina:
- EYE PROTECTION ABSOLUTELY REQUIRED! Your eye is no match for
bits of diamond and alumna grit flying about.
- BREATHING PROTECTION MANDATORY! Alumna dust from such grinding
is very fine and should be expected to cause long-term lung problems if
inhaled, similar to silicosis. For small quantities of dust (cutting a few
small pieces of tubing) it may be best to work outside in a stiff breeze
or with a strong exhaust fan pulling the dust outside to an unoccupied
area, then clean up the area with a damp sponge. A good, properly-fit dust
mask intended for very fine dust should be worn as a back-up. For larger
quantities of dust, refer to current OSHA regulations for appropriate
protection.
- HEARING PROTECTION RECOMMENDED. High-speed grinding without
hearing protection may reduce your ability to appreciate good music or
hear dinner bells.
GAS CHOICES AND COMPRESSED GAS SAFETY
It is not absolutely necessary to run a Fusor-type machine on deuterium.
You can do interesting, educational, and worthwhile non-nuclear tests using
trace background gas in the system (typically mostly air or water vapor).
Hydrogen gas is also readily available and cheap, and behaves very much like
deuterium except that the ions move faster (they are half the mass of
deuterium ions) and will not fuse at the voltages the machine will operate
at. Heavy inert gases such as argon or xenon would make pretty glows in a
Fusor, but be warned that they multiply ionize, and so multiply the
acceleration of the grid: you might be using 10kV and getting 40 keV ions if
the charge on each ion is +4, for example. This might get you into a
radiation hazard area.
UNDER NO CIRCUMSTANCES SHOULD YOU USE BOTTLED OXYGEN OR OTHER
OXIDIZING GASES, AS THESE PRESENT SPECIAL AND VERY SERIOUS SAFETY
CONCERNS!
Both hydrogen and deuterium are extremely flammable (remember the
Hindenberg)! Use them in a well-ventilated area, as free from ignition
sources as possible, and limit the amount by using the smallest practical
container. Use appropriate hardware and use it appropriately (I shudder to
remember the day I found a large 20-liter hydrogen bottle empty due to a cut
piece of teflon tubing that had been used instead of the recommended
stainless steel).
The pressure in a commercial gas cylinder is typically up in the
thousands of pounds per square inch. This presents all sorts of hazards.
Information on safe handling is available from gas suppliers and in most lab
safety books. Get the information, read it, and take it seriously.
Deuterium is slightly toxic when incorporated into biological materials,
such as water. This is due to the additional mass: deuterium atoms react
slightly slower than hydrogen atoms, which is enough to throw off some
biochemical systems.
You should not need much deuterium or hydrogen if you keep the system
tight and are not sloppy with your usage. A "lecture bottle" contains more
than enough if used wisely. Recent prices for lecture bottles of deuterium
run from $140 to $250. In addition, you will need a pressure regulator
intended for hydrogen, preferably a two-stage regulator, designed for the
lowest pressure you can get, probably 15 psig maximum. These ain't exactly
cheap.
WARNING -- The use of a sample bottle recommended below is safe
ONLY IF THE BOTTLE IS FILLED TO EXTREMELY LOW PRESSURE and ONLY IF THE
BOTTLE IS FIRST EVACUATED OF AIR. The intent is to avoid the need for a
regulator and to eliminate the hazards of high-pressure gas, but this
advantage would be lost if the cylinder is filled beyond the lowest pressure
needed, typically 10 psig or less, or filled with an explosive mixture of
air and hydrogen.
An interesting way around the need for pressure bottles and expensive
regulators may be available if you are in a position to share a bottle of
gas or can pursuade someone to give you a small sample. In this case, all
you need is a "sample bottle" of perhaps a half a liter or liter capacity.
You could potentially use a clean 14- or 16-ounce propane bottle for this,
if you carefully fill it to no more than 10 psig. To fill any sample bottle,
you must first pump out all the air or gas using a vacuum pump. Then fill it
partway and pump it out again, repeating this several times. Finally, fill
it up to the desired pressure. Mechanical pressure/vacuum gages for this
task are readily available from industrial suppliers for around $10.
Hydrogen and deuterium gas should be run through hard lines wherever
possible, preferably stainless steel. The best connections are Swage-Lok or
similar systems employing two-piece ferrules. Use these according to the
manufacturer's directions. Copper lines may break at the connections if
flexed. If flexible lines are required, welding gas hoses may be the safest
bet.
Leak test all joints using soapy water or a leak-check solution such as
"Snoop". Not only will this help avoid fire or explosion, it may save the
considerable heartache of finding the contents of an expensive bottle of
deuterium have mysteriously vanished.
GRID CONSTRUCTION
Figure 2 in the Analog article shows the general construction of a
grid. Stainless steel welding wire of about 0.025" diameter works fairly
well and is cheap and readily available. However, if you can obtain wire
made from one of several "refractory metals" it will be helpful, as
stainless steel grids are not especially durable, and may have a life of
only minutes at power levels sufficient to produce measurable fusion (expect
the inner grid to run red hot from ion bombardment if significant fusion is
occurring). Tantalum, rhenium, and tungsten are considered refractory
metals.
Tantalum has the lowest melting point of the three, but is a big
improvement over stainless steel. It spot-welds readily if it is cleaned of
all oxide and contamination prior to welding.
Rhenium is an excellent choice, but expensive. Fortunately you do
not require much. It also spot-welds fairly easily.
Tungsten has the highest melting point of any metal, and it is
reasonably readily available. Tungsten can be run white-hot without melting
(although even tungsten grids can be damaged by extreme ion bombardment).
Unfortunately, tungsten tends to make brittle spot-welds. If you are among
the privileged few who know how to make durable welds with this
temperamental metal, by all means consider using it. Otherwise, expect
problems.
After the center grid is made, spot-weld a wire to one grid-wire
intersection and bend it out perpendicular to the grid. This will be the
lead to bring power to the grid. Run this wire through an alumina tube to
the chamber's high voltage feedthrough, where it can usually be attached by
a mechanical friction joint (I sometimes wind the end of the wire into a
coil and slip it over the lead of the feedthrough). You may have to remove
or adjust the grid so be sure your attachment method allows this.
Overlapping sections of different-diameter tubing may be used to cover the
joint. The outer grid is either grounded to the chamber walls or may be
connected to its own feedthrough if you wish to try adjusting its voltage,
which may be useful for controlling ionization.
The spot-welder I use for these grids is an older model with a capacity
of 80 joules (80 watt-seconds). I usually adjust it down to 20-30 joules. A
spot-welder uses a bank of electrolytic capacitors charged up to a fairly
high voltage, typically up to 400 volts. When the desired energy level is
reached (calculated from the capacitance and voltage by a simple formula
found in basic electronics texts) the capacitor bank is discharged through a
step-down transformer so that a pulse of low voltage but very high current
is produced in the secondary winding. This pulse is delivered to a pair of
copper rods with the "work" pinched between them. A good weld requires
modest pressure be applied to the parts being joined, and a short jolt of
high current flow through the point of contact between them.
Practice with scrap wire before building a grid, particularly if you are
using expensive, hard-to-find metal.
There are probably several useful tricks one can do with grid design
which will improve IEC performance. Be aware, however, that you are not the
only person doing such experiments. While the original patents held by P. T.
Farnsworth and Robert Hirsch, on which the Analog article were based,
have long since expired, there are active patents in the field. The Fusion
Studies Laboratory under Dr. George Miley at the University of Illinois at
Urbana-Champaign holds active patents, and since they have commercial
aspirations in the IEC area you can expect them to get a bit testy if you
steal their ideas. There is also some activity at Los Alamos and elsewhere.
If you plan to try improved designs, particularly if you intend to publish
or sell them, you would be well advised to do a patent search and retain a
lawyer skilled in the field. The list of patents at the end of this article
is incomplete, intended only as a starting place.
SOME THEORETICAL TIPS
This section presumes a good general science knowledge, including basic
physics, chemistry, and electricity, plus basic algebra and geometry and the
ability to solve "word problems".
I will not attempt to give a complete tutorial on the subject of nuclear
fusion or the theoretical basis for the Farnsworth Fusor or Inertial
Electrostatic Confinement (IEC). Dive into the many textbooks on nuclear
physics and look up the referenced IEC papers for a complete understanding.
What follows is only a brief introduction to give the reader an idea of the
scope of the problem.
For each nuclear reaction involving collisions, which is the type
involved in fusion, there is a parameter called "cross section". There are
many types of cross section which may be encountered, but the one you are
most interested in is "fusion cross section." This is not a fixed number,
but typically increases with the kinetic energy (and velocity and
"temperature") of the particle or particles involved (there is a maximum
energy above which cross section will fall).
Cross sections are all given in units of area. Essentially, they are
"target size". Imagine you have a shooting gallery full of targets, and you
are randomly firing small BBs into the gallery. You would calculate the
likelihood of hitting a target from the area of the target (the cross
section), their density (how much target area is there per area of shooting
gallery), and how many BBs you fire at them.
In the case of fusion, picture that the target is a ball of modeling
clay. If it is hit by a slow BB, the BB will just bounce off, so the cross
section for the BB sticking is zero. If the BB is traveling a little faster,
it may stick, but only if it hits dead center, so the target acts as if it
is smaller than its actual physical size. If traveling even faster, the BB
will stick if it hits anyplace on the target. If traveling a lot faster than
that, the BB may just go clean through the target, possibly splattering the
target in the process. Thus, fusion cross sections are typically negligible
at low energy, rise progressively as energy increases, to a maximum above
which cross section falls with energy.
Hydrogen has a poor cross section. The nuclei are protons, with a mass of
1 AMU and a charge of +1, so Coulomb repulsion (mutual repulsion of like
charges) is high compared to the mass. Deuterium nuclei are a proton and a
neutron, with a mass of 2 a charge still +1, so they have more momentum
compared to their charge with which they can better overcome the Coulomb
barrier. Furthermore, the charge is on one end of the nucleus, and if the
nuclei approach neutron to neutron they have a slight advantage. Deuterium
thus has a much better fusion cross section than hydrogen. Tritium is two
neutrons and a proton, mass 3 and charge still +1. Deuterium-Tritium fusion
is about the easiest of the fusion reactions to do, i.e. it has the highest
cross section and can go at fairly low kinetic energy.
The most commonly used unit of cross section is the "barn." One barn is
1E-24 (one times ten to the minus 24) square centimeters, or 1E-30 square
meters. Pretty small, you say? Actually, legend has it that a physicist was
one day measuring collision cross sections of various materials and found a
really big one. This esteemed researcher said something like, "Wow, that
cross section is as big as a barn!" People who work with subatomic particles
frequently have a unique perspective, not to mention a peculiar sense of
humor when it comes to naming things. Typical D-D fusion cross sections at
the 10keV range in an IEC machine are around 0.0002 barns (in the central
region) to 0.001 barns (for head-on collisions).
Fusion reaction cross sections are published in a number of nuclear
physics texts, but should be used with some caution. Be aware of the type of
collision being described by the cross section. The interaction between two
nuclei hitting head-on at the same energy, two nuclei hitting at an angle at
the same energy, two nuclei hitting at random energies and angles within the
spread of a thermal "Maxwellian" distribution at a given temperature, and a
fast nucleus hitting one which is essentially stationary are all very
different cases. Much of the published data is for "thermonuclear" machines
such as tokamaks, and is not quite the same as for monoenergetic ions in an
IEC machine. You may have to go back to the fundamental data to get a useful
cross section.
The basic steps involved in calculating an approximate reaction rate
are:
- 1) Determine the energy (charge on the ion times grid voltage to give
electron volts) and corresponding fusion cross section (look up or
calculate from known data). The cross section is usually denoted with the
Greek letter lower-case sigma. Two cross sections are used for IEC
machines, the head-on equal-energy cross section and a lower cross section
assuming that most collisions are at angles resulting from spherical
convergence.
- 2) Determine the velocity of the striking nucleus. The velocity will
be non-relativistic, and can be determined by the classical formula:
KE = 1/2 m V^2 (Kinetic Energy = one half particle mass times
velocity squared)
or doing a little algebra --
V = sqrt(2 KE/m)
Be sure you pick a consistent system of units. In the SI system you
must convert electron volts to joules (KE), the mass (m) of the nucleus to
kilograms, and then the velocity (V) will work out in meters/second.
- 3) Calculate sigma V (the product of cross section and velocity).
- 4) Here is the messy part. Calculate the density of striking nuclei
and the density of target nuclei. In the case of the D-D IEC machine
described in the Analog article these values are the same.
- 4A) The simplified approach to doing this is to assume all (or some
large fraction of) the current to the inner grid is due to ion flow,
each with a charge of +1 (there are 6.24e18 charges per ampere).
- 4B) One then multiplies the current times a "ion recirculation
factor", starting with the geometric transparency of the inner grid (how
much of the spherical surface is blocked by grid wires). If 90% of the
sphere is open space, and only 10% is blocked by wire, this should mean
that an ion will hit the grid on only one pass in ten, so the first
guess at the "ion recirculation factor" would be 10 (as we shall see in
a minute, it can actually be much higher than this). Current times
recirculation factor gives an estimate of the number of ions passing the
grid per second.
- 4C) From the velocity of the ions and the diameter of the grid you
can calculate how long each ion is inside the grid.
- 4D) From how long each ion is in the grid and how many ions per
second pass through the grid you can calculate the overall density
inside the grid.
- 4E) It is best to break this volume up into two or more concentric
spheres or shells, with the central region a sphere the size of the
visible bright spot in the very center. Density will be progressively
higher as you approach the center. Fusion rate is strongly dependent on
density.
- 5) For each shell, calculate the fusion rate. In the central region
you use the lower angle-averaged cross section because the ions are
hitting from all angles. In the shells surrounding it you use the higher
head-on cross section, because the ions are traveling almost perfectly
radially and only hit head-on. Fusion rate is essentially the product of
the density of striking nucleus (ns), the density of target nucleus (nt),
and the sigma V value already calculated. Since the target and striking
densities are the same in this case you can just use ion density n so:
Fusion rate per unit volume = n n sigma V.
From there it is just a matter of geometry to calculate the volume of
each region calculated, work up the fusion rate in that volume, and add up
the rates.
This is an APPROXIMATION. More exact solutions require calculus to
avoid the use of discrete shells and to account for the velocity slightly
falling off inside the inner grid (due to the mutual repulsion of ions
concentrating there). Various loss mechanisms due to other forms of
collision should also be taken into account, as well as various
non-idealities. These are discussed in some of the referenced papers.
However, down in the root of all of these fusion calculations you will find
the factors "n-squared sigma V". It is important to recognize that the
fusion rate goes up very strongly with increasing n (density) and somewhat
strongly with velocity V (which is a function of energy, which also raises
sigma).
If you look at specific cases of the calculation above, you will realize
that a good, sharp focus of the central region of ion convergence will
greatly increase the reaction rate there. In a well-focused machine this
region produces most of the fusion, in spite of the lower reaction cross
section, because the density is so very high there. In poorly-focused cases
the region of head-on collisions outside the central focus region becomes
more important: the density is lower but the higher cross section and
greater volume compensate somewhat.
One interesting note: George Miley's group at the University of
Illinois at Urbana-Champaign's Fusion Studies Institute have identified a
phenomenon they call "star mode" (it was seen by Dr. Hirsch as well and
other workers as well, so is not new, but some of the earlier workers
apparently did not fully appreciate the significance of it). If you get the
machine described working right, you will see this mode, which essentially
amounts to channelization of the ions into distinct rays converging on the
center. The rays go through the grid openings, staying clear of the grid
wires. In star mode, the effective transparency of the inner grid increases
substantially over the geometrical transparency, possibly increasing
transparency from a typical 90% to in excess of 99%, which increases ion
recirculation up to 100 or even higher. Star mode also seems to sharpen the
focus of the central convergence region. One key to star mode is achieving
good alignment of the inner and outer grids.
Another interesting note: the pressure measured in the vacuum
chamber by most common methods appears to be nearly useless for calculating
density. If you assume the neutral gas is at room-temperature you might
calculate a "mean free path" for collision between ions and neutral
background gas and conclude the ions cannot travel far enough to achieve
decent recirculation. However, performance of these machines suggests
otherwise. Do remember that any background neutrals in such a machine will
be slapped around rather rudely by the ions, which will typically have a
kinetic temperature of 11604 K per electron volt, or 116 million K for a
measly 10 kV drive voltage. Thus, the background neutrals should be expected
to be rapidly heated to very high temperatures, which should greatly lower
their density at any given pressure. Also, commonly used thermocouple gages
assume the gas COOLS the gage, so if the gas is actually hotter then
the blazes of Hell, the gage will lie to you.
In essence, ion density responsible for the reaction will be a function
of electrical current to the inner grid, recirculation efficiency, voltage,
and sharpness of focus. The ions are largely trapped, thus do not interact
with a pressure gage. No attempt should be made to try to determine ion
density from chamber pressure as measured by a gage stuck out on the wall of
the chamber. The gage pressure IS important, however, for achieving
the neutral density needed to start up glow discharge mode, the easiest way
of running these machines.